Confirm moisture exposure
Separate dry bathrooms, humid utility rooms and splash-prone wet areas. This helps choose WPC leaf structure, edge sealing, frame material and ventilation requirements.
Published by VisFurn
VISFURN is the project-door brand of Tianjin Visfurn Furniture Co., Ltd. This product page supports buyers comparing the proposed door set, specifications and quotation scope.

WPC Doors · Humid-Area Interior Series
A WPC door-set option for humid-area project review. Confirm the leaf, frame, architrave, seals, threshold, hardware and installation conditions together for the expected room exposure.
Evidence boundary: This is a design and specification review page, not a waterproof or fire certificate. Check the proposed assembly and required documents before approval. Images are visual references, not verified installation or test records.
Project pricing · subject to specification
Overview
For a bathroom or utility-room opening, record where humidity, cleaning water or direct splash reaches the leaf, bottom edge, frame and trim. Confirm the offered materials and junction details for the complete set rather than assuming that a WPC face establishes the performance of every component.
Ask for the proposed leaf section, edge treatment, finish sample and hardware fixing details. The specification references below are a starting point for quotation; an approved sample and product drawing must identify the construction to be supplied. A catalogue image does not establish scratch, water, fire or acoustic performance.

Buyer Answer
Consider this design for an interior opening after the proposed door set has been reviewed for the actual room conditions. For bathrooms and utility rooms, distinguish ambient humidity from direct water exposure and specify cleaning, ventilation, threshold and hardware conditions. Do not extend the selection to a rain-exposed exterior opening or a fire/acoustic requirement without separate product evidence.
Technical Review
| Material | Wood Plastic Composite (WPC) — wood fibre + PVC resin + stabilisers |
|---|---|
| Core Structure | Extruded hollow-rib (standard) / foamed solid core (upgrade) |
| Leaf Thickness | 40 mm (1-9/16") / 45 mm (1-3/4") |
| Standard Sizes | 800×2000 mm / 900×2100 mm · 30"×80" / 32"×80" / 36"×80" |
| Surface Finish | Laminated PVC film over UV primer — woodgrain and solid colour options |
No waterproof, fire or acoustic rating is established by this page. If the project requires tested performance, request the report for the offered assembly and check its construction, size and hardware scope before approval. Use the WPC sample approval checklist and construction comparison guide to record what is confirmed and what remains pending.

Applications
Apartment, hotel and student-housing schedules can include different room exposures even when the doors share one visual design. Separate bedroom, bathroom and service-room door marks. A healthcare or other specialist opening needs its own cleaning, access and documentation review; no cost saving or suitability follows from the material name alone.
Confirm lock bores, hinge mortices and any closer reinforcement against the selected hardware drawing before production. Send the opening schedule, finish direction and hardware requirements for review.
Packaging & Shipping
Every order is prepared for long-haul maritime transport and for what happens after it lands. Cartons are labelled by opening reference, so a site team can move pallets floor by floor without unwrapping them to find out what is inside.

FAQ
No. The WPC material name and catalogue images do not establish waterproof, fire or acoustic performance. Request product-specific evidence for the proposed leaf, frame, edges and hardware, and confirm the permitted exposure and installation conditions before approval.
Hollow-rib and solid-core describe different internal constructions. Ask for the offered section, finished weight, edge details and hardware fixing method. Do not infer acoustic performance, closer suitability or freight cost from the core label alone.
Matching WPC frames and architraves can be reviewed with the same finish direction as the leaf. Confirm the complete opening schedule before quotation.
Leaf dimensions, film colours, lock bores, hinge mortices and closer reinforcement can be reviewed against the project opening schedule and hardware drawings.
The minimum order is 50 sets in total, with at least 10 sets per model. Mixed designs, sizes and colours can be reviewed against the final door schedule.
Each leaf can be protected with EPE foam, PE shrink film, reinforced cardboard corner protectors and export pallets. Final packing and container planning should be confirmed against the order schedule.
A useful bathroom or utility-room review identifies the exposure, frame, threshold and hardware protection as well as the leaf. Keep unresolved requirements visible in the quotation.
Separate dry bathrooms, humid utility rooms and splash-prone wet areas. This helps choose WPC leaf structure, edge sealing, frame material and ventilation requirements.
Send finished wall thickness after tile or plaster so the WPC frame and architrave can cover the opening correctly without site trimming.
Confirm lock, hinge, screw and latch finish for cleaning chemicals and humidity. Stainless or corrosion-resistant hardware may be needed for high-use wet areas.
For hotels, schools and apartments, label WPC bathroom doors by floor, room type and opening ID to reduce installation confusion after container arrival.
These are visual planning references, not evidence of a completed installation, tested cross-section or certified performance. Use an identified physical sample and approved drawing to confirm the actual construction, finish and hardware.


